Info Datasheet Operation and installation instructions

Application

  • Cold rooms
  • Refrigerated Warehouse
  • Sensitive Produce
  • Fruit and Vegetables
  • Meat, Fish, Poultry
TÜV HACCP

AGHN

Wall/ceiling unit coolers

Features

Advantages

  • Robust design
  • Suction fans, wide air throw
  • Large variety of types
  • Many design types

Easy to Install

  • Ceiling mounting brackets for easy installation
  • Empty tube for defrost sensor
  • Side cover with hinges and quick-release fastener
  • Schrader valve on outlet

Inspection and Cleaning

  • Hinged tray

HACCP Hygiene Certificate

  • Suitable for rooms used for food processing
  • All materials used approved for foodstuffs
  • Drip tray with edges inclined at 45° angle
  • Easy to clean

High Operational Reliability and Leak-Safety

  • Proven Güntner floating coil principle (refrigerantcarrying tubes do not make contact with the casing;increases the heat exchanger’s service life)

Technical details

Heat Exchanger

  • Aligned or staggered tube pattern
  • Special copper tubes for HFC, coolant and CO2
  • Stainless steel tubes for NH3 or steel, hot-dip galvanised
  • Surface-corrugated aluminium fins for high heat transfer

Casing

  • Corrosion-resistant aluminium alloy AlMg up to 500 mm fan diameter
  • Galvanized steel, from 710 mm fan diameter
  • Powder-coated with RAL 9003
  • Hinged side cover with hinges
  • Fans positioned at an angle (from 710 mm) improve the air throw and defrosting behaviour

Tray

  • Hinged and thermally-decoupled (condensation free)
  • Separate drip plate
  • Corrosion-resistant aluminium alloy AlMg
  • Powder-coated with RAL 9003
  • Large condensation drain with 45° incline

Fans

  • Proven quality fans
  • Standard with two speeds (for fan diameter of 500 mm)
  • Motor protection with thermocontacts
  • 230 V, 1~, 50 Hz or 60 Hz (up to construction size 450)
  • 400 V, 3~, 50 Hz or 60 Hz
  • Wired on connection socket in factory (GHF)

Product Types / Refrigerant / Capacity

 

 

 

 

 

References

Precise cooling: Fish production in Vietnam

Precise cooling: Fish production in Vietnam

The new fish factory of Hung Vuong Ben Tre produces frozen food in line with HACCP directives for the European and Russian market every day. About 1,500 employees process approx. 250 tonnes of seafood per day on a total area of 30,000 m². Güntner evaporators, air coolers and coils reliably provide normal-temperature and low-temperature storage rooms and freezers with cold. A thermowave plate heat exchanger is used here to connect the primary with the secondary circuit.

 

Project description (372 KB)

New concept: penthouse coolers

New concept: penthouse coolers

For the storage-warehouse in Wasserburg, dairy producer Bauer selected an innovative Penthouse solution. The NH3 regrigerating plant cools two deep freeze stores and three area with temperatures above zero.

 

Project description (2.13 MB)

Cooling chain on rails

Cooling chain on rails

Australia in the year 2002: After two years of

planning and construction work, the first railwaycooling chain starts successfully. Güntner Group units are in service at the SCT refrigeration facilities in Perth and Melbourne.

 

Project description (355 KB)

Penthouse concept for seafood in Vietnam

Penthouse concept for seafood in Vietnam

One of the largest logistics centers in Vietnam uses 36 NH3 evaporators in penthouse cooler design with a refrigerating capacity of 1841 kW.

 

Project description (1.29 MB)

Media

Videos

Cubic Vario presentation @ Chillventa 2014

Download

Publications

Air coolers, air flow and temperature distribution in large cold stores

Air coolers, air flow and temperature distribution in large cold stores

Download

How the air throw of air coolers is influenced by the spatial geometry and by air cooling

How the air throw of air coolers is influenced by the spatial geometry and by air cooling

Download

Influence of heat exchanger design on dehumidification and frost formation

Influence of heat exchanger design on dehumidification and frost formation

Download

Sensible use of energy-saving fans

Sensible use of energy-saving fans

Download

Energy saving on the low-pressure side of a refrigerating plant

Energy saving on the low-pressure side of a refrigerating plant

Download

Tips

subcooling and system efficiency

subcooling and system efficiency

Download

Accessory

  • Epoxy-resin coated fins
  • Double, insulated tray
  • Core tubes made of stainless steel
  • Casing and tray made of stainless steel
  • Factory-fitted thermostatic expansion valve
  • Güntner Streamer
  • Defrost flap for quick, efficient defrosting
  • Air sock connection
  • Fan casing for 45° / 90° downblow
  • Legs

Share this page